Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Catheter Cardiovasc Interv ; 95(2): 175-184, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31033154

RESUMO

OBJECTIVES: To assess the long-term safety and efficacy of a sirolimus-eluting stent with bioresorbable polymer (BP-SES; Ultimaster), in comparison to a benchmark everolimus-eluting, permanent polymer stent (PP-EES; Xience), in a prespecified subgroup of patients with multivessel coronary artery disease (MVD) enrolled in the CENTURY II trial. BACKGROUND: The use of coronary stenting in high-risk subgroups, like MVD patients, is rising. The clinical evidence, including long-term comparative analysis of the efficacy and safety benefits of different new-generation drug eluting stents, however, remains insufficient. METHODS: Among 1,119 patients (intention-to-treat) enrolled in the CENTURY II prospective, randomized, single-blind, multicenter trial, a prespecified subgroup of 456 MVD patients were allocated by stratified randomization to treatment with BP-SES (n = 225) or PP-EES (n = 231). The previously reported primary endpoint of this study was freedom from target lesion failure (TLF: a composite of cardiac death, target vessel-related myocardial infarction [MI] and clinically-indicated target lesion revascularization) at 9 months. RESULTS: In this MVD substudy, baseline patient, lesion and procedure characteristics were similar between the treatment arms. At 1 and 5 years, both BP-SES and PP-EES displayed low and comparable rates of TLF (5.3 vs. 7.8%; p = .29 and 10.2 vs. 13.4%; p = .29), and definite or probable stent thrombosis (0.4 vs. 1.3%; p = .33 and 0.9 vs. 1.7%; p = .43), respectively. Composite endpoint of cardiac death and MI, and patient-oriented composite endpoint of any death, MI, and coronary revascularizations were also similar. CONCLUSIONS: These results confirm good long-term safety and efficacy of the studied bioresorbable polymer stent in this high-risk patient population.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Estenose Coronária/terapia , Stents Farmacológicos , Everolimo/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Polímeros/química , Sirolimo/administração & dosagem , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Estenose Coronária/fisiopatologia , Europa (Continente) , Everolimo/efeitos adversos , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Estudos Prospectivos , Desenho de Prótese , República da Coreia , Fatores de Risco , Método Simples-Cego , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
2.
Cardiovasc Revasc Med ; 17(6): 355-61, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27156201

RESUMO

BACKGROUND: To investigate clinical outcomes of percutaneous coronary intervention using a sirolimus-eluting stent with bioresorbable polymer, Ultimaster (BP-SES) compared with a permanent polymer everolimus-eluting stent, Xience (PP-EES) in patients with high risk (ST-segment elevation and non-ST-segment elevation myocardial infarction) acute coronary syndromes (ACS) enrolled in the CENTURY II trial. METHODS: CENTURY II is a prospective, multicenter, randomized, single blind, controlled trial comparing BP-SES and PP-EES, with primary endpoint of target lesion failure (TLF) at 9month post-stent implantation. Out of 1123 patients enrolled in CENTURY II trial, 264 high risk ACS patients were included in this subgroup analysis, and the clinical outcomes including target lesion failure (TLF), target vessel failure (TVF), cardiac death, myocardial infarction, and stent thrombosis were evaluated at 24months. RESULTS: The baseline clinical, angiographic and procedural characteristics were similar between two groups. At 24months, TLF occurred in 6.3% of patients receiving a BP-SES and 6.5% of patients receiving a PP-EES (P=0.95); TVF was 6.3% in patients receiving a BP-SES and 9.4% in patients receiving a PP-EES (P=0.36). There were no significant differences in cardiac death, myocardial infarction and stent thrombosis rate. CONCLUSIONS: BP-SES achieved similar safety and efficacy outcomes as PP-EES in this ACS subgroup of CENTURY II study, at 24-month follow-up. This finding is hypothesis-generating and needs to be confirmed in larger trials with longer follow-up.


Assuntos
Implantes Absorvíveis , Síndrome Coronariana Aguda/terapia , Fármacos Cardiovasculares/administração & dosagem , Stents Farmacológicos , Everolimo/administração & dosagem , Infarto do Miocárdio sem Supradesnível do Segmento ST/terapia , Intervenção Coronária Percutânea/instrumentação , Polímeros/química , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/mortalidade , Idoso , Angiografia Coronária , Reestenose Coronária/etiologia , Europa (Continente) , Feminino , Humanos , Japão , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio sem Supradesnível do Segmento ST/mortalidade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Estudos Prospectivos , Desenho de Prótese , Recidiva , República da Coreia , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Método Simples-Cego , Trombose/etiologia , Fatores de Tempo , Resultado do Tratamento
3.
EuroIntervention ; 11(13): 1468-74, 2016 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-27107311

RESUMO

AIMS: Prior percutaneous coronary intervention (PCI) is increasingly encountered in acute coronary syndrome (ACS) patients, with uncertain significance. We sought to evaluate the impact of prior PCI in ACS patients. METHODS AND RESULTS: Patients with ACS enrolled in the prospective PROSPECT registry underwent three-vessel intravascular ultrasound and virtual histology evaluation after successful PCI of the culprit lesion(s). We identified patients with prior PCI (>6 months before index ACS) and compared their outcomes to those without prior PCI. Time-to-event for major adverse cardiac events (MACE) was estimated up to three years, and the independent association between prior PCI and MACE was evaluated in a multivariable model. Among 696 patients enrolled, 77 (11.1%) had prior PCI. They were older and more likely to have prior myocardial infarction, chronic kidney disease, and congestive heart failure. At three years, patients with prior PCI had significantly higher rates of cardiac death, rehospitalisation for worsening angina, and MACE (adjusted HR=1.73 [95% CI: 1.09, 2.75], p=0.02), independent of other comorbidities and intravascular ultrasound findings. CONCLUSIONS: Prior PCI was noted in over 10% of patients with ACS and was associated with higher mortality and morbidity, independent of other comorbidities. Prior PCI should be considered a high-risk feature when evaluating ACS patients.


Assuntos
Síndrome Coronariana Aguda/mortalidade , Síndrome Coronariana Aguda/terapia , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea/mortalidade , Sistema de Registros , Idoso , Angioplastia Coronária com Balão/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/métodos , Estudos Prospectivos , Fatores de Risco , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...